Series 573 3-way solenoid operated valves are specifically engineered to meet the design, quality and stress limits imposed by the ASME Boiler Code - Section III requirements.  These valves offer tight sealing for liquid or gas applications.

Absolute zero leakage to the local environment is provided by a completely welded construction throughout the pressure envelope.  O-ring and mechanical fed options are available.

This series is qualified to IEEE 344.  Seismic and stress analysis reports are available when required.

Valve operation is accomplished by energizing the solenoid.  The plunger moves directly to open the lower seat and shut off the upper seat.  A spring returns the plunger to its original position upon de-energization of the solenoid.  The valve can be designed for Normally Open, Normally Closed or Diverter operation as the application requires.

Extreme reliability is inherent due to rugged design, simplicity of operation and a minimum number of moving parts.  Isolation standoffs prevent excessive heat transfer to the solenoid operator.  Internal parts are contoured to retard buildup of contamination and sludge.  Compact, light weight design provides excellent resistance to seismic vibration and shock.  A completely enclosed and encapsulated coil ensures continuous operation during a LOCA event.

Features and Options:

Absolute zero leakage to the environment.  No packings, bellows, or diaphragms.
Valve ratings: ANSI class 150 to 2500.
Direct Lift construction.  No minimum Delta P required.
High cycle life.  Over 100,000 operations in most applications.
Resistant to contamination and sludge buildup.
ASME Section III, Classes 1,2, and 3.
Available in Normally Close, Normally Open or Diverter configurations.
Available Fail Safe Closed, Fail Safe Open or Fail in Last Position.
Body material:  Standard: Stainless Steel  
Hardfaced or elastomer seats optional.
Position indication switches available for remote status indication.
Line connection:  Standard:  Socket weld, Optional:  Butt Weld or Tube Extensions.
Solenoid operator is constructed of Class H materials or better.  120 VAC or 125 VDC.  Other voltages available.
All electrical components totally enclosed.  Meets minimum of NEMA 4 or better.
Solenoid and switch assemblies readily accessible for removal or maintenance without disturbing the pressure boundary.
Stress and seismic analysis available.  Qualified to IEEE 344.
Radiation resistance:  Standard 2 x 108 rads.
 